Attack Fire Dry Powder (Stored Pressure) ABC/BC type Fire Extinguishers are suitable for class A, B & C/BC fires as well as Electrical Fire. This is a versatile and multipurpose Fire Extinguisher and is easily identifiable to use on any class of fire. The extinguisher contains Mono Ammonium Phosphate / Sodium-bi-carbonate based Dry Powder as extinguishing medium and is pressurized with dry nitrogen gas. It is fitted with pressure gauge and its needle in green zone indicates the serviceability of the extinguisher.
Fire Extinguisher Specification Table
MODEL
BC/ABC 1 KG
BC/ABC2KG
BC/ABC4KG
BC/ABC6KG
BC/ABC 9 kg
IS Specification
15683
15683
15683
15683
15683
Type of Fire
BC/AB&C
BC/AB&C
BC/AB&C
BC/AB&C
BC/AB&C
Extinguisher Type
Stored Pressure
Stored Pressure
Stored Pressure
Stored Pressure
Stored Pressure
Extinguishing Media
Dry Power (Sodium-bi-carbonate/Mono Ammonium Phosphate)
IS : 4308 / IS :14609
Pressurized with N2 gas
Dry Power (Sodium-bi-carbonate/Mono Ammonium Phosphate)
IS : 4308 / IS :14609
Pressurized with N2 gas
Dry Power (Sodium-bi-carbonate/Mono Ammonium Phosphate)
IS : 4308 / IS :14609
Pressurized with N2 gas
Dry Power (Sodium-bi-carbonate/Mono Ammonium Phosphate)
IS : 4308 / IS :14609
Pressurized with N2 gas
Dry Power (Sodium-bi-carbonate/Mono Ammonium Phosphate)
IS : 4308 / IS :14609
Pressurized with N2 gas
Min Effective Discharge(%)
90
DO
DO
90
DO
Min Jet Length (mtr)
2
2
4
6
6
Discharge Time(sec)
More than 8 Sec
More than 8 Sec
More than 13 Sec
More than 13 Sec
More than 13 Sec
Test Pressure(kgf/cr)
35
35
35
35
35
Charged Pressure(kgf/cm)
15
15
15
15
15
Operation Position
Upright
Upright
Upright
Upright
Upright
Operating Valve
Squeeze Grip Type with Nozzle
Squeeze Grip Type with Nozzle
Squeeze Grip Type
with Discharge Pipe
& Nozzle
Squeeze Grip Type
with Discharge
Pipe & Nozzle
Squeeze Grip Type with
Discharge Pipe & Nozzle
Operating Temperature
−10° to 55°C
−10° to 55°C
−10° to 55°C
−10° to 55°C
−10° to 55°C
//////
CARBON DIOXIDE TYPE FIRE EXTINGUISHER
Co2 type fire extinguisher contains CO2 gas, Which is non-conductive, non-corrosive and suitable for quenching Class B & C fires involving flammable liquid i.e. oil, solvent, flammable gases, industrial & electrical equipment, etc.
CO2 Fire Extinguisher Specification Table
PORTABLE
TROLLEY MOUNTED
MODEL
CO2 2kg
CO2 4.5 kg
CO2 6.5kg
CO2 9kg
CO2 22.5kg
IS Specification
15683
15683
16018
16018
16018
Type of Fire
B & C Class
B & C Class
B & C Class
B & C Class
B & C Class
Extinguishing Media
CO2 Gas
CO2 Gas
CO2 Gas
CO2 Gas
CO2 Gas
Discharge Time (secs.)
More than 8 Sec
More than 8 Sec
10 to 20
15 to 36
20 to 60
Discharge Hose
–
1 Mtr.
1 Mtr.
2 Mtr.
5 Mtr.
Min Effective Discharge %
95
95
95
95
95
Operation Method
Upright
Upright
Upright
Upright
Upright
Expellent
Self
Self
Self
Self
Self
Operating Valve
Wheel/Squeeze Grip
Type
Wheel/Squeeze Grip
Type
Wheel/Squeeze
Grip Type
Wheel/Squeeze
Grip Type
Wheel/Squeeze
Grip Type
Operating TemperatureºC
-20 to 55ºC
-20 to 55ºC
-20 to 55ºC
-20 to 55ºC
-20 to 55ºC
Fire Rating
8B
21B
21B
34B
34B
//////
WATER ST0RED PRESSURE | GAS TYPE FIRE EXTINGUISHER
Co2 type fire extinguisher contains CO2 gas, Which is non-conductive, non-corrosive and suitable for quenching Class B & C fires involving flammable liquid i.e. oil, solvent, flammable gases, industrial & electrical equipment, etc.
Water CO2 Fire Extinguisher Specification Table
MODEL
W/CO2 6
W/CO2 9
W/CO2 50
IS Specification
15683
15683
16018
Type of Fire
A Class
A Class
A Class
Extinguishing Type
Stored Pressure/ Gas
Cartridge
Stored Pressure/ Gas Cartridge
Gas Cartridge
Extinguishing Media
Water
Water
Water
Capacity (Ltr.)
6 L
9 L
50 L
Min Effective Discharge %
95
95
95
Min Jet Length (mtr.)
6
6
10
Discharge Time (sec.)
More than 13 Sec
More than 13 Sec
60 to 180
Test Pressure (kgf/cnY)
35
35
35
Expellent CO2
Gas Cartridge (gms) IS : 494a’
Nz gas / 60 gms Gas Cartridge
Nz gas / 60 gms Gas Cartridge
2 Kg / 300 gms Gas Cartridge
Operating Method
Upright
Upright
Upright
Caution
Not to be used on Electrical Fire
Not to be used on Electrical Fire
Not to be used on Electrical Fire
MECHANICAL FOAM STORED PRESSURE/ GAS TYPE FIRE EXTINGUISHER
Mechanical foam type fire extinguisher is most effective on class A & B (Flammable and volatile liquid i.e., oil, petroleum, diesel, points, alcohol etc.) where fast fire knockdown and blanketing effect is essential. Aqueous Film Forming Foam property it is also used in Class A Fire. It contains AqueousFilm Forming Foam (AFFF) compound, it has been used in the extinguisher to form an aqueous film and thick blanket of foam on the surface of fire, excluding the supply of oxygen thereby extinguishing the fire and preventing re-ignition
Mechanical Foam Fire Extinguisher Table
MODEL
MF 6
MF 9
MF 50
IS Specification
15683
15683
16018
Type of Fire
A & B Class
A & B Class
A & B Class
Extinguishing Type
Stored Pressure/ Gas Cartridge
Stored Pressure/ Gas Cartridge
Stored Pressure/ Gas Cartridge
Extinguishing Media
Water & AFFF IS:4989
Water & AFFF IS:4989
Water & AFFF IS:4989
Capacity (Ltr.)
6 L
6 L
50 L
Min Effective Discharge %
95
95
95
Min Jet Length (mtr.)
6
6
10
Discharge Time (sec.)
More than 13 Sec
More than 13 Sec
60 to 180
Test Pressure (kgf/cm²)
35
35
35
Expellent CO2 Gas Cartridge (gms) IS : 494a
N₂ gas / 60 gms Gas Cartridge
N₂ gas / 60 gms Gas Cartridge
2 kg / 300 Gms Gas Cartridge
Operating Method
Upright
Upright
Upright
Caution
Not to be used on Electrical Fire
Not to be used on Electrical Fire
Not to be used on Electrical Fire
DRY CHEMICAL POWDER BC/ABC TROLLEY MOUNTED TYPE FIRE EXTINGUISHER
Attack Fire Dry Powder (Stored Pressure) ABC/BC type Fire Extinguishers are suitable for
class A, B & C/BC fires as well as Electrical Fire. This is a versatile and multipurpose Fire Extinguisher and is easily identifiable to use on any class of fire. The extinguisher contains Mono Ammonium Phosphate / Sodium-bi-carbonate based Dry Powder as extinguishing medium and is pressurized with dry nitrogen gas. It is fitted with pressure gauge and its needle in green zone indicates the serviceability of the extinguisher.
DCP Fire Extinguisher Specification Table
MODEL
DCP 25 KG
DCP 50 KG
DCP 75 KG
IS Specification
16018
16018
16018
Type of Fire
BC/ABC
BC/ABC
BC/ABC
Type of Extinguisher
Dry Powder Type
Dry Powder Type
Dry Powder Type
Extinguisher Media
Dry Powder
Dry Powder
Dry Powder
Jet Length (mtrs.)
6
8
10
Min Effective Discharge (%)
85
85
85
Min Discharge Time (secs.)
25 to 30
40 to 50
50 to 60
Test Pressure (kgf/cm²)
30
30
30
Expellent CO2 Gas Cartridge
2 Kg CO2
2 Kg CO2
2 Kg CO2
Operating Position
Upright
Upright
Upright
Operating TemperatureºC
−5º to 55º C
−5º to 55º C
−5º to 55º C
Fire Rating
34 B
55 B
55 B
CLEAN AGENT STORED PRESSURE TYPE FIRE EXTINGUISHER
A clean agent type fire extinguisher is non-conductive and suitable for all classes of fire: A, B & C. It does not leave any residue after discharge, hence suitable for computer sever room, electronic circuitry, telephone exchange, and other sensitive equipments. It is a perfect replacement for Halon 1211 and is environmentally friendly. Available in capacities of 1kg, 2kg, 4kg & 6kg in portable fire extinguishers and 2kg, Skg & 10kg in modulartype
DRY POWDER TYPE FIRE EXTINGUISHER
Attack Fire Dry Powder (Stored Pressure) ABC/BC type Fire Extinguishers are suitable for class A, B & C/BC fires as well as Electrical Fire. This is a versatile and multipurpose Fire Extinguisher and is easily identifiable to use on any class of fire. The extinguisher contains Mono Ammonium Phosphate / Sodium-bi-carbonate based Dry Powder as extinguishing medium and is pressurized with dry nitrogen gas. It is fitted with pressure gauge and its needle in green zone indicates the serviceability of the extinguisher.
IS : 4308 / IS :14609
Pressurized with N2 gas
IS : 4308 / IS :14609
Pressurized with N2 gas
IS : 4308 / IS :14609
Pressurized with N2 gas
IS : 4308 / IS :14609
Pressurized with N2 gas
IS : 4308 / IS :14609
Pressurized with N2 gas
with Discharge Pipe
& Nozzle
with Discharge
Pipe & Nozzle
Discharge Pipe & Nozzle
//////
CARBON DIOXIDE TYPE FIRE EXTINGUISHER
Co2 type fire extinguisher contains CO2 gas, Which is non-conductive, non-corrosive and suitable for quenching Class B & C fires involving flammable liquid i.e. oil, solvent, flammable gases, industrial & electrical equipment, etc.
Type
Type
Grip Type
Grip Type
Grip Type
//////
WATER ST0RED PRESSURE | GAS TYPE FIRE EXTINGUISHER
Co2 type fire extinguisher contains CO2 gas, Which is non-conductive, non-corrosive and suitable for quenching Class B & C fires involving flammable liquid i.e. oil, solvent, flammable gases, industrial & electrical equipment, etc.
Cartridge
Gas Cartridge (gms) IS : 494a’
MECHANICAL FOAM STORED PRESSURE/ GAS TYPE FIRE EXTINGUISHER
Mechanical foam type fire extinguisher is most effective on class A & B (Flammable and volatile liquid i.e., oil, petroleum, diesel, points, alcohol etc.) where fast fire knockdown and blanketing effect is essential. Aqueous Film Forming Foam property it is also used in Class A Fire. It contains AqueousFilm Forming Foam (AFFF) compound, it has been used in the extinguisher to form an aqueous film and thick blanket of foam on the surface of fire, excluding the supply of oxygen thereby extinguishing the fire and preventing re-ignition
Gas Cartridge (gms) IS : 494a
DRY CHEMICAL POWDER BC/ABC TROLLEY MOUNTED TYPE FIRE EXTINGUISHER
Attack Fire Dry Powder (Stored Pressure) ABC/BC type Fire Extinguishers are suitable for
class A, B & C/BC fires as well as Electrical Fire. This is a versatile and multipurpose Fire Extinguisher and is easily identifiable to use on any class of fire. The extinguisher contains Mono Ammonium Phosphate / Sodium-bi-carbonate based Dry Powder as extinguishing medium and is pressurized with dry nitrogen gas. It is fitted with pressure gauge and its needle in green zone indicates the serviceability of the extinguisher.
CLEAN AGENT STORED PRESSURE TYPE FIRE EXTINGUISHER
A clean agent type fire extinguisher is non-conductive and suitable for all classes of fire: A, B & C. It does not leave any residue after discharge, hence suitable for computer sever room, electronic circuitry, telephone exchange, and other sensitive equipments. It is a perfect replacement for Halon 1211 and is environmentally friendly. Available in capacities of 1kg, 2kg, 4kg & 6kg in portable fire extinguishers and 2kg, Skg & 10kg in modulartype